Site Regulations  
   
Home
 
Login  
About Hospital Safety Center  
Contact Us
 
Sitemap
 
Subscribe  
       Free Resources
Hospital Safety Connection
E-Newsletter

 
Important Safety Websites  
Mac's Safety Space  
       Safety Center Members
Briefings on Hospital Safety  
Special Reports  
Healthcare Security Alert  
Safety Talk  
       Platinum Members
Regulatory Compliance Database  
Risk Assessment Workstations  
 
Hazard Vulnerability Analysis
Interim Life Safety Measures
Infection Control Risk Assessment
 
Forms and Checklists Library  
       Consulting
Greeley Hospital Safety Institute  

 

 

     

Classification of flammable and combustible liquids

PRINT THIS STORY | ARCHIVES | DOWNLOAD THIS DOCUMENT

The following tool guideline is originally published in the Complete Guide to Laboratory Safety, Third Edition by Terry Jo Gile. Click here for more information.

According to OSHA 1910.106(a)(19) , a flammable liquid means any liquid having a flash point below 100ºF (37.8ºC), except mixtures with flash points of 100ºF or higher, the total of which makes up 99% or more of the mixture.

Flammable liquids are divided into three classes:

  Flash Point Boiling Point Examples
Class 1A Below 73ºF (22.8ºC) Below 100ºF (37.8ºC) Acetaldehyde, ethyl ether, pentane
Class 1B Below 73ºF (22.8ºC) At or above 100ºF (37.8ºC) Acetone, gasoline, benzene
Class 1C At or above 73ºF (22.8ºC) Below 100ºF (37.8ºC) Turpentine, xylene, isopropanol

A combustible liquid refers to any liquid with a flash point at or above 100ºF (37.8ºC), according to OSHA 1910.106(a)(18).

Combustible liquids are divided into two classes:

  Flash Point Examples
Class II At or above 100ºF (37.8ºC) and below 140ºF (60ºC),
except any mixture having components with flashpoints
of 200ºF (93.3ºC) or higher, the volume of
which make up 99% or more of the total volume of
the mixture
Acetic acid, cyclohexane
Class III At or above 140ºF (60ºC)  
Class IIIA At or above 140ºF (60ºC) and below 200ºF (93.3ºC),
except any mixture having components with flash
points of 200ºF (93.3ºC) or higher, the volume of
which makes up 99% or more of the total volume of
the mixture
Formic acid and cyclohexanol
Class IIIB At or above 200ºF (93.3ºC) Formalin and picric acid

* When a combustible liquid is heated for use to within 30ºF (16.7ºC) of its flash point, it shall be handled in accordance with the requirements for the next lower class of liquids, according to 1910.106(a)(18)(iii).




Subscribe Now!
Sign up for our free e-newsletter
Analyzing the Hospital Life Safety Survey

This book by former Joint Commission life safety surveyor Brad Keyes, CHSP, provides a practical, strategic approach to the life safety survey process. Keyes offers a room-by-room, floor-by-floor analysis of the life safety measures you need to have in place to avoid costly citations. He simplifies confusing Joint Commission standards and CMS requirements and reveals what you should be focusing on to pass your next life safety survey.

Order online at HCPro’s Healthcare Marketplace.

About Us | Terms of Use | Privacy Statement | Contact Us
Copyright © 2012. Hospital Safety Center.